SRP-25

Manufactured by: SRP-25

// AC/DC Power Supplies / Open Frame | Enclosed | U-Chassis

Download PDF Specs »

Features:

  • RoHS Compliant
  • Advanced SMT Design
  • Fits 1U Application
  • One to Three Outputs
  • EN 60950-1ITE Certification
  • EN 60601-1 Medical Certification
  • Class B Emissions per EN 55011/22
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • Optional Chassis and Cover

General Specifications

  • Manufacturer Integrated Power Designs
  • Form Factor Open Frame
  • Power 25 Watts
  • Input 85-264 VAC
  • Outputs Single, Dual or Triple
  • Warranty 2 Year Warranty

Models

Model #

Output

  • SRP-25-1001 3.3V
  • SRP-25-3003 3.3V, 6V, 5V
  • SRP-25-1002 5V
  • SRP-25-2003 5V, -5V
  • SRP-25-2002 5V, 12V
  • SRP-25-2001 5V, 24V
  • SRP-25-3001 5V, 12V, -12V
  • SRP-25-3002 5V, 15V, -15V
  • SRP-25-1003 12V
  • SRP-25-2004 12V, -12V
  • SRP-25-1004 15V
  • SRP-25-2005 15V, -15V
  • SRP-25-1005 24V
  • SRP-25-1006 48V

Mechanical

  • Dimensions 2.25 x 4.0 x 0.96 inches
  • Operating Temperature 0°C- +70°C
  • MTBF 100,000 Hours min, MIL-HDBK-217F, 25°C, GB
  • Cooling Method Free air convection
  • Agency Approvals General: Protection Class- I, Over voltage catagory- II, Pollution Degree- 2
    UL: UL 60950-1, UL 60601-1, CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No.601-1-M90
    with updates 1 and 2
    TUV: EN 60950-1:2001, EN 60601-1/A2:1995
    CE: Low voltage dir

Output

  • Voltage Accuracy Output 1: ±0.25%
    Output 2: ±5%
    Output 3: ±2%
  • Line Regulation 0.50%
  • Load Regulation Output 1: 0.5%
    Output 2: 5%
    Output 2 (2003): 6%
    Output 3: 1%
  • Minimum Load 10%
  • Protections Over voltage: Output 1: 110%-150%
    Over Current: Output 3: 110%
    Over power: Output 1&2: 110%, cycle on/off, auto recovery