General Specifications
- Manufacturer Integrated Power Designs
- Form Factor Enclosed
- Power 30 Watts
- Input 85-264 VAC
- Outputs Single, Dual, Triple or Quadruple
- Warranty 2 Year Warranty
Models
Model #
Output
- SRP-30A-1001 3.3V
- SRP-30A-4001 3.3V, 5V, 12V, -12V
- SRP-35A-1002 5V
- SRP-30A-2003 5V, -5V
- SRP-30A-2002 5V, 12V
- SRP-30A-2001 5V, 24V
- SRP-30A-4002 5V, 3.3V, 12V, -12V
- SRP-30A-4003 5V, -5V, 12V, -12V
- SRP-30A-4004 5V, -5V, 15V, -15V
- SRP-30A-3001 5V, 12V, -12V
- SRP-30A-3002 5V, 15V, -15V
- SRP-30A-4005 5V, 24V, 12V, -12V
- SRP-30A-4006 5V, 24V, 15V, -15V
- SRP-35A-1003 12V
- SRP-30A-2004 12V, -12V
- SRP-35A-1004 15V
- SRP-30A-2005 15V, -15V
- SRP-35A-1005 24V
- SRP-35A-1006 48V
Mechanical
- Dimensions 3"x 6"x 2"
- Operating Temperature 0°C- +70°C
- MTBF 100,000 Hours min, MIL-HDBK-217F, 25°C, GB
- Cooling Method Free air convection
-
Agency Approvals
General: Protection Class- I, Over voltage catagory- II, Pollution Degree- 2, Ingress Protection- IP30
UL: UL 60950-1, UL 60601-1, CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No.601-1-M90 with updates 1 and 2
TUV: EN 60950-1:2001, EN 60601-1/A2:1995
Output
-
Voltage Accuracy
Output 1: ±0.25%
Output 2: ±5%
Output 3: ±3%
Output 4: ±3% - Line Regulation 0.50%
-
Load Regulation
Output 1: 7%
(1001): 10%
(4001): 12%
Output 2: 5%
Output 2 (4001,3&4): 10%
(2003, 4002): 12%
Output 3: 1%
Output 4: 1% - Minimum Load 10%
-
Protections
Over voltage: Output 1: 110%-150%
Over Current: Output 3&4: 110%
Over power: Output 1&2: 110%, cycle on/off, auto recovery