General Specifications
- Manufacturer Integrated Power Designs
- Form Factor Open Frame
- Power 40 Watts
- Input 85-264 VAC
- Outputs Sinlge, Dual, Triple, or Quadruple
- Warranty 2 Year Warranty
Models
Model #
Output
- SRP-40A-1001 3.3V
- SRP-40A-2007 3.3V, 5V
- SRP-40A-4001 3.3V, 5V, 12V, -12V
- SRP-40A-4007 3.3V, 5V, -24V, -51.6V
- SRP-40A-1002 5V
- SRP-40A-2003 5V, -5V
- SRP-40A-2002 5V, 12V
- SRP-40A-2001 5V, 24V
- SRP-40A-4002 5V, 3.3V, 12V, -12V
- SRP-40A-4003 5V, -5V, 12V, -12V
- SRP-40A-4004 5V, -5V, 15V, -15V
- SRP-40A-3001 5V, 12V, -12V
- SRP-40A-3002 5V, 15V, -15V
- SRP-40A-3005 5.1V, 15V, 9V
- SRP-40A-4005 5V, 24V, 12V, -12V
- SRP-40A-4006 5V, 24V, 15V, -15V
- SRP-40A-1007 9V
- SRP-40A-1003 12V
- SRP-40A-1004 15V
- SRP-40A-3003 24V, 15V, -15V
- SRP-40A-3004 14.5V, -14.5V, 5V
- SRP-40A-2004 12V, -12V
- SRP-40A-2005 15V, -15V
- SRP-40A-2006 30V, -15V
- SRP-40A-2008 6V, 9V
- SRP-40A-1005 24V
- SRP-40A-1006 48V
Mechanical
- Dimensions 2.50 x 4.25 x 1.2 inches
- Operating Temperature 0°C- +70°C
- MTBF 100,000 Hours min, MIL-HDBK-217F, 25°C, GB
- Cooling Method Free air convection
-
Agency Approvals
General: Protection Class- I, Over voltage catagory- II, Pollution Degree- 2
UL: UL 60950-1, UL 60601-1, CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No.601-1-M90
with updates 1 and 2
TUV: EN 60950-1:2001, EN 60601-1/A2:1995
CE: Low voltage dir
Output
-
Voltage Accuracy
Output 1: ±0.25%
Output 2: ±5%
Output 3: ±3%
Output 4: ±3% - Line Regulation 0.50%
-
Load Regulation
Output 1: 0.5%
Output 2: 5%
(2003,4002):7%
Output 3: 0.5%
Output 4: 0.5% - Minimum Load 10%
-
Protections
Over voltage: Output 1: 110%-150%
Over Current: Output 3&4: 110%
Over power: Output 1&2: 110%, cycle on/off, auto recovery