SRP-40A

Manufactured by: SRP-40A

// AC/DC Power Supplies / Open Frame | Enclosed | U-Chassis

Download PDF Specs »

Features:

  • RoHS Compliant
  • Universal 85~264 VAC input
  • Advanced SMT Design
  • Compact Size
  • Fits 1U Application
  • EN 60950-1 ITE Certification
  • EN 60601-1 Medical Certification
  • Class B Emissions per EN 55011/22
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • Optional Chassis and Cover

General Specifications

  • Manufacturer Integrated Power Designs
  • Form Factor Open Frame
  • Power 40 Watts
  • Input 85-264 VAC
  • Outputs Sinlge, Dual, Triple, or Quadruple
  • Warranty 2 Year Warranty

Models

Model #

Output

  • SRP-40A-1001 3.3V
  • SRP-40A-2007 3.3V, 5V
  • SRP-40A-4001 3.3V, 5V, 12V, -12V
  • SRP-40A-4007 3.3V, 5V, -24V, -51.6V
  • SRP-40A-1002 5V
  • SRP-40A-2003 5V, -5V
  • SRP-40A-2002 5V, 12V
  • SRP-40A-2001 5V, 24V
  • SRP-40A-4002 5V, 3.3V, 12V, -12V
  • SRP-40A-4003 5V, -5V, 12V, -12V
  • SRP-40A-4004 5V, -5V, 15V, -15V
  • SRP-40A-3001 5V, 12V, -12V
  • SRP-40A-3002 5V, 15V, -15V
  • SRP-40A-3005 5.1V, 15V, 9V
  • SRP-40A-4005 5V, 24V, 12V, -12V
  • SRP-40A-4006 5V, 24V, 15V, -15V
  • SRP-40A-1007 9V
  • SRP-40A-1003 12V
  • SRP-40A-1004 15V
  • SRP-40A-3003 24V, 15V, -15V
  • SRP-40A-3004 14.5V, -14.5V, 5V
  • SRP-40A-2004 12V, -12V
  • SRP-40A-2005 15V, -15V
  • SRP-40A-2006 30V, -15V
  • SRP-40A-2008 6V, 9V
  • SRP-40A-1005 24V
  • SRP-40A-1006 48V

Mechanical

  • Dimensions 2.50 x 4.25 x 1.2 inches
  • Operating Temperature 0°C- +70°C
  • MTBF 100,000 Hours min, MIL-HDBK-217F, 25°C, GB
  • Cooling Method Free air convection
  • Agency Approvals General: Protection Class- I, Over voltage catagory- II, Pollution Degree- 2
    UL: UL 60950-1, UL 60601-1, CAN/CSA-C22.2 No. 60950-1-03, CAN/CSA-C22.2 No.601-1-M90
    with updates 1 and 2
    TUV: EN 60950-1:2001, EN 60601-1/A2:1995
    CE: Low voltage dir

Output

  • Voltage Accuracy Output 1: ±0.25%
    Output 2: ±5%
    Output 3: ±3%
    Output 4: ±3%
  • Line Regulation 0.50%
  • Load Regulation Output 1: 0.5%
    Output 2: 5%
    (2003,4002):7%
    Output 3: 0.5%
    Output 4: 0.5%
  • Minimum Load 10%
  • Protections Over voltage: Output 1: 110%-150%
    Over Current: Output 3&4: 110%
    Over power: Output 1&2: 110%, cycle on/off, auto recovery